$1,103.17
  • CMSX-P-SE-C-U-F1-D-130-C
  • 3929540

Overview

Features

  • Digital, electropneumatic positioner design
  • Double-acting mode of operation
  • Safety position - pneumatic outlets closed design characteristics
  • Optional mounting position
  • With accessories type of mounting
  • Potentiometer functional principle of measuring system
  • 7-segment display
  • LCD display display
  • With backlighting display
  • Via display and keys setting options
  • 0.5% size of dead zone
  • 10% size of dead zone
  • 0.3MPA operating pressure
  • 0.8MPA operating pressure
  • 3BAR operating pressure
  • 8BAR operating pressure
  • 43.5PSI operating pressure
  • 116PSI operating pressure
  • Compressed air to ISO 8573-1:2010 [7:4:4] operating medium
  • Lubricated operation not possible note on operating and pilot medium
  • 130L2 standard nominal flow rate
  • 24V nominal operating voltage dC
  • 21.6V operational voltage range dC
  • 26.4V operational voltage range dC
  • 600MA max. current consumption
  • For operating voltage connections reverse polarity protection
  • 80KOH connection resistance
  • 0 - 10 V digital input, signal range
  • 0 - 20 mA digital input, signal range
  • 4 - 20 mA digital input, signal range
  • 0 - 24 mA analogue inputs, max. dynamic range
  • 0 - 11 V analogue inputs, max. dynamic range
  • 0.5% analogue inputs, linearity error at 25 °C
  • 0.02YUP analogue inputs, temperature coefficient
  • 16 bit analogue inputs, resolution
  • Yes analog inputs, overload protection
  • No analogue inputs, electrical isolation
  • 4 - 20 mA digital output, signal range
  • 600OHM analogue outputs, max. load impedance
  • 0.5% analogue outputs, linearity error at 25°C
  • 0.02YUP analogue outputs, temperature coefficient
  • 12 bit analogue outputs, resolution
  • Yes analogue outputs, reverse polarity protection
  • Yes analog outputs, short circuit current rating
  • Yes analog outputs, overload protection
  • No analogue outputs, galvanic isolation
  • To IEC 61131-2, type 3 characteristic for inputs
  • PNP switching input
  • NPN switching input
  • Yes digital inputs, reverse polarity protection
  • Yes, via optocoupler digital inputs, electrical isolation
  • Yes digital outputs, reverse polarity protection
  • 3 x PNP or 3 x NPN, switchable switching output
  • 100 mA digital outputs, output current
  • Yes digital outputs, short circuit current rating
  • Yes digital outputs, overload protection
  • Yes, via optocoupler digital outputs, electrical isolation
  • 3x digital output electrical connection 1, function
  • Analogue output electrical connection 1, function
  • Analogue input electrical connection 1, function
  • Digital input electrical connection 1, function
  • Power supply electrical connection 1, function
  • Load power supply electrical connection 1, function
  • Terminal strip electrical connection 1, connection type
  • Screw terminal electrical connection 1, connector system
  • 13 electrical connection 1, number of connections/cores
  • 0.6NM electrical connection 1, tightening torque
  • 1.5I2 electrical connection 1, conductor cross section
  • External path/angle sensor electrical connection 2, function
  • Terminal strip electrical connection 2, connection type
  • Screw terminal electrical connection 2, connector system
  • 3 electrical connection 2, number of connections/cores
  • 0.6NM electrical connection 2, tightening torque
  • 1.5I2 electrical connection 2, conductor cross section
  • M12 x 1.5 for electrical connection 2 cable fitting
  • M20 x 1.5 for electrical connection 1 cable fitting
  • 3 m for electrical connection 2 max. cable length
  • 30 m for electrical connection 1 max. cable length
  • 5 - 95% relative air humidity
  • Non-condensing relative air humidity
  • IP65 degree of protection
  • 2 - Moderate corrosion stress corrosion resistance class cRC
  • Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 shock resistance
  • As per EN 60068-2-29 shock resistance
  • Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 vibration resistance
  • As per EN 60068-2-6 vibration resistance
  • 3 pollution degree
  • RCM trademark approval
  • To EU EMC Directive cE mark (see declaration of conformity)
  • In accordance with EU RoHS Directive cE mark (see declaration of conformity)
  • To UK instructions for EMC cE marking (see declaration of conformity)
  • To UK RoHS instructions cE marking (see declaration of conformity)
  • PC-reinforced material housing
  • PC material screen
  • Wrought aluminium alloy, anodised material base plate
  • High-alloy stainless steel material shaft
  • High-alloy stainless steel material coupling
  • High-alloy stainless steel material screws
  • NBR material seals
  • PA material cable gland
  • PA material blanking plug
  • VDMA24364-B2-L lABS (PWIS) conformity
  • RoHS-compliant note on materials
  • 970G product weight
  • 190 mm x 105 mm x 130 mm dimensions (W x l x h)
  • -5GC ambient temperature to 60GC ambient temperature
  • -20GC to 60GC storage temperature
  • 3 to 7 - 13 mm for electrical connection 1 permissible cable diameter
  • Pneumatic connection g1/8