- CPX-AP-I-4DI4DO-M12-5P
- 8086603
- CPX-AP-I-4DI4DO-M12-5P
- By Festo
- FREE Shipping on orders of $1,000 or more
- FREE Lifetime Tech Support
Overview
Features
- 30 x 170 x 35 mm dimensions (W x l x h)
- On H-rail via accessories type of mounting
- With through-hole type of mounting
- 129G product weight
- 5 - 95% relative air humidity
- Non-condensing relative air humidity
- IP65 degree of protection
- IP67 degree of protection
- Unused connections sealed note on degree of protection
- 1 - Low corrosion stress corrosion resistance class cRC
- 30 m outputs max. cable length
- 30 m inputs max. cable length
- 50 m system communication max. cable length
- Power supply according to nominal voltage note on max. cable length
- VDMA24364-B2-L lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- C UL us listed (OL) approval
- UL E239998 certificate issuing authority
- RoHS-compliant note on materials
- PA material housing
- PC material housing
- Die-cast zinc, nickel-plated material housing
- FPM material o-ring
- Diagnostics per module diagnostics via lED
- Load power supply diagnostics via lED
- Status per channel diagnostics via lED
- Load switch-off diagnostics per internal communication
- Short-circuit/overload in output signal diagnostics per internal communication
- Short circuit/overload in sensor supply diagnostics per internal communication
- Electronics/sensors overvoltage diagnostics per internal communication
- Load overvoltage diagnostics per internal communication
- Electronics/sensors undervoltage diagnostics per internal communication
- Load undervoltage diagnostics per internal communication
- 4 number of outputs
- System communication XF10 IN / XF20 OUT communication interface, function
- 2x socket communication interface, connection type
- M8x1, D-coded according to EN 61076-2-114 communication interface, connection technology
- 4 communication interface, number of pins/wires
- AP communication interface, protocol
- Yes communication interface, shielding
- Incoming electronics/sensors and load power supply, function
- Plugs power supply, connection type
- M8x1, A-coded to EN 61076-2-104 power supply, connection system
- 4 power supply, number of pins/wires
- Outgoing electronics/sensors and load power transmission, function
- Socket power transmission, connection type
- M8x1, A-coded to EN 61076-2-104 power transmission, connection technology
- 4 power transmission, number of pins/wires
- SELV/PELV fixed power supplies required note regarding operating voltage
- Note voltage drop note regarding operating voltage
- 24V nominal operating voltage dC of load
- ± 25 % permissible voltage fluctuation of load
- 24V nominal dC operating voltage, electronics/sensors
- ± 25% permissible voltage fluctuations for electronics/sensors
- 2 x 4 A (external fuse required) max. power supply
- Typically 35 mA intrinsic current consumption at nominal operating voltage for electronics/sensors
- Typically 10 mA intrinsic current consumption at nominal operating voltage load
- 10MS power failure bridging
- Yes reverse polarity protection
- Digital input electrical connection input, function
- 2x socket electrical connection input, connection type
- M12x1, A-coded to EN 61076-2-101 electrical connection input, connector system
- 5 electrical connection input, number of connections/cores
- 4 number of inputs
- To IEC 61131-2, type 3 characteristic for inputs
- Signal 0: <= 5 V switching level
- Signal 1: >= 11 V switching level
- PNP (positive switching) switching logic for inputs
- 2-wire sensors to IEC 61131-2 switching logic for inputs
- 3-wire sensors to IEC 61131-2 switching logic for inputs
- 0.1 ms input debounce time
- 3 ms input debounce time
- 10 ms input debounce time
- 20 ms input debounce time
- Internal electronic fuse per module fuse protection of inputs (short circuit)
- 1.8A max. residual current of inputs per module
- No electrical isolation of inputs between channels
- Yes electrical isolation of inputs between channel - internal communication
- Digital output electrical connection output, function
- 2x socket electrical connection output, connection type
- M12x1, A-coded to EN 61076-2-101 electrical connection output, connector system
- 5 electrical connection output, number of connections/cores
- According to IEC 61131-2, type 0.5 characteristic for outputs
- PNP (positive switching) switching logic for outputs
- Internal electronic fuse per channel fuse protection of outputs (short circuit)
- Signal change 0->1: < 200 µs output delay with ohmic load
- Signal change 1->0: < 200 µs output delay with ohmic load
- 2A max. residual current outputs per module
- No electrical isolation of outputs between channels
- Yes electrical isolation of outputs between channel - internal communication
- 0.5 A max. power supply per channel
- -20GC ambient temperature to 50GC ambient temperature
- -40GC to 70GC storage temperature