  • CPX-E-CEC-M1-EP
  • 4252744
  • CPX-E-CEC-M1-EP
  • By Festo
  • FREE Shipping
  • Manufacturer has 20 in stock.
    Additional 2-3 days to process. Call for expedite options.

Overview

Features

  • 75.9 mm x 82.5 mm x 124.3 mm dimensions (W x l x h)
  • 18.9MM grid dimension
  • With H-rail type of mounting
  • 10 max. number of modules
  • 288G product weight
  • Vertical mounting position
  • Horizontal mounting position
  • -5GC ambient temperature
  • 50GC ambient temperature
  • -5 - 60°C for vertical installation note on ambient temperature
  • 95 % relative air humidity
  • Non-condensing relative air humidity
  • IP20 degree of protection
  • 0 - No corrosion stress corrosion resistance class cRC
  • Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 vibration resistance
  • Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 shock resistance
  • PELV protection against direct and indirect contact
  • VDMA24364 zone III lABS (PWIS) conformity
  • To EU EMC Directive cE mark (see declaration of conformity)
  • In accordance with EU RoHS Directive cE mark (see declaration of conformity)
  • To UK instructions for EMC cE marking (see declaration of conformity)
  • To UK RoHS instructions cE marking (see declaration of conformity)
  • KC-EMV kC mark
  • RCM trademark approval
  • C UL us listed (OL) approval
  • UL E239998 certificate issuing authority
  • RoHS-compliant note on materials
  • PA material housing
  • Force mode diagnostics via lED
  • Module status diagnostics via lED
  • Network status diagnostics via lED
  • Network status, engineering port 1 diagnostics via lED
  • Network status, engineering port 2 diagnostics via lED
  • EtherCAT® network status diagnostics via lED
  • Network status, port 1 diagnostics via lED
  • Network status, port 2 diagnostics via lED
  • Run diagnostics via lED
  • Power supply, electronics/sensors diagnostics via lED
  • Load power supply diagnostics via lED
  • System fault diagnostics via lED
  • DIL switch for RUN/STOP operator controls
  • Rotary switch for address setting operator controls
  • Optional: CDSB operator unit operator controls
  • DHCP iP address setting
  • Via CODESYS iP address setting
  • Optional: via operator unit CDSB iP address setting
  • Ethernet fieldbus interface
  • ACD (Address Conflict Detection) field bus, protocol
  • DLR (Device Level Ring) field bus, protocol
  • EtherNet/IP field bus, protocol
  • EtherNet/IP QoS field bus, protocol
  • EtherNet/IP Quickconnect field bus, protocol
  • SNMP field bus, protocol
  • Bus connection incoming/outgoing fieldbus interface, function
  • 2x socket field bus, connection type
  • RJ45 field bus, connection system
  • 995789 fieldbus interface, connection pattern
  • 8 field bus, connection pattern
  • Yes field bus interface, electrical isolation
  • 100 Mbit/s field bus interface, transmission rate
  • Ethernet fieldbus interface 2, type
  • CoE fieldbus interface 2, protocol
  • EoE fieldbus interface 2, protocol
  • EtherCAT® fieldbus interface 2, protocol
  • FoE fieldbus interface 2, protocol
  • Outgoing bus connection fieldbus interface 2, function
  • Socket fieldbus interface 2, connection type
  • RJ45 fieldbus interface 2, connection technology
  • 995789 fieldbus interface 2, connection pattern
  • 8 fieldbus interface 2, number of pins/wires
  • Yes fieldbus interface 2, galvanic isolation
  • 100 Mbit/s fieldbus interface 2, transmission rate
  • 2x socket ethernet interface, connection type
  • EasyIP ethernet interface, protocol
  • Modbus® TCP ethernet interface, protocol
  • OPC UA ethernet interface, protocol
  • TCP/IP ethernet interface, protocol
  • Diagnostics ethernet interface, function
  • Switch ethernet interface, function
  • RJ45 ethernet interface, connection system
  • 995789 ethernet interface, connection pattern
  • 8 ethernet interface, number of pins/wires
  • 10 Mbit/s ethernet interface, transmission rate
  • 100 Mbit/s ethernet interface, transmission rate
  • 64AD max. address volume, inputs
  • 512AD fieldbus interface, max. address volume for inputs
  • 64AD max. address volume, outputs
  • 512AD fieldbus interface, max. address volume for outputs
  • Diagnostic memory system parameters
  • Fail-safe response system parameters
  • System start system parameters
  • Channel alarms bundling module parameters
  • Undervoltage diagnostics module parameters
  • Channel alarms for undervoltage module parameters
  • Process value representation of analogue modules module parameters
  • Control unit CDSB configuration support
  • CODESYS V3 configuration support
  • CoDeSys V3 with SoftMotion additional functions
  • 512 MB RAM cPU data
  • Dual Core 766 MHz cPU data
  • Micro SD <= 32 GB storage medium
  • USB memory stick <= 32 GB storage medium
  • Electronics and sensors power supply, function
  • Terminal strip power supply, connection type
  • > 4 A and UL 2x terminal strip for power supply power supply, note on connection type
  • Spring-loaded terminal power supply, connection system
  • 995847 power supply, connection pattern
  • 4 power supply, number of pins/wires
  • 24V nominal dC operating voltage, electronics/sensors
  • ± 25% permissible voltage fluctuations for electronics/sensors
  • 0.2I2 power supply, conductor diameter
  • 1.5I2 power supply, conductor diameter
  • 0.2 - 2.5 mm² for flexible conductors without wire end sleeves power supply, note on conductor diameter
  • 8A max. power supply
  • Typically 150 mA intrinsic current consumption at nominal operating voltage for electronics/sensors
  • 20MS power failure bridging
  • 24 V sensor supply against 0 V sensor supply reverse polarity protection
  • USB 2.0 uSB-interface
  • CODESYS provided by Festo programming software
  • 100 MB user program program memory
  • Approx. 200 µs/1 k instruction processing time
  • And others function modules
  • Read CPX-E module diagnostics function modules
  • CPX-E diagnostic status function modules
  • Copy CPX-E diagnostic trace function modules
  • 3WCH buffering time real-time clock
  • 120 kB retentive data flag
  • CODESYS variable concept flag
  • Yes isolation channel - internal bus
  • -20GC to 70GC storage temperature