Festo CPX-E-CEC-M1-PN Controller

- CPX-E-CEC-M1-PN
- 4252743
- CPX-E-CEC-M1-PN
- By Festo
- FREE Shipping
-
Manufacturer has 2 in stock.Additional 2-3 days to process. Call for expedite options.
Overview
Features
- 75.9 mm x 82.5 mm x 124.3 mm dimensions (W x l x h)
- 18.9MM grid dimension
- With H-rail type of mounting
- 10 max. number of modules
- 288G product weight
- Vertical mounting position
- Horizontal mounting position
- -5GC ambient temperature
- 50GC ambient temperature
- -5 - 60°C for vertical installation note on ambient temperature
- 95 % relative air humidity
- Non-condensing relative air humidity
- IP20 degree of protection
- 0 - No corrosion stress corrosion resistance class cRC
- Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 vibration resistance
- Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 shock resistance
- PELV protection against direct and indirect contact
- VDMA24364 zone III lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- C UL us listed (OL) approval
- UL E239998 certificate issuing authority
- RoHS-compliant note on materials
- PA material housing
- Force mode diagnostics via lED
- Module status diagnostics via lED
- Network fault diagnostics via lED
- Network status, engineering port 1 diagnostics via lED
- Network status, engineering port 2 diagnostics via lED
- EtherCAT® network status diagnostics via lED
- Network status, port 1 diagnostics via lED
- Network status, port 2 diagnostics via lED
- Run diagnostics via lED
- Power supply, electronics/sensors diagnostics via lED
- Load power supply diagnostics via lED
- System fault diagnostics via lED
- Service required diagnostics via lED
- DIL switch for RUN/STOP operator controls
- Optional: CDSB operator unit operator controls
- DHCP iP address setting
- Via CODESYS iP address setting
- Optional: via operator unit CDSB iP address setting
- Ethernet fieldbus interface
- LLDP field bus, protocol
- MRP, MRPD (ring redundancy) field bus, protocol
- PROFINET I&M0 .. 3 field bus, protocol
- PROFINET IO field bus, protocol
- PROFINET RT field bus, protocol
- PROFINET shared device field bus, protocol
- SNMP field bus, protocol
- Bus connection incoming/outgoing fieldbus interface, function
- 2x socket field bus, connection type
- RJ45 field bus, connection system
- 995789 fieldbus interface, connection pattern
- 8 field bus, connection pattern
- Yes field bus interface, electrical isolation
- 100 Mbit/s field bus interface, transmission rate
- Ethernet fieldbus interface 2, type
- CoE fieldbus interface 2, protocol
- EoE fieldbus interface 2, protocol
- EtherCAT® fieldbus interface 2, protocol
- EtherCAT master fieldbus interface 2, protocol
- FoE fieldbus interface 2, protocol
- Outgoing bus connection fieldbus interface 2, function
- Socket fieldbus interface 2, connection type
- RJ45 fieldbus interface 2, connection technology
- 995789 fieldbus interface 2, connection pattern
- 8 fieldbus interface 2, number of pins/wires
- Yes fieldbus interface 2, galvanic isolation
- 100 Mbit/s fieldbus interface 2, transmission rate
- 2x socket ethernet interface, connection type
- EasyIP ethernet interface, protocol
- Modbus® TCP ethernet interface, protocol
- OPC UA ethernet interface, protocol
- TCP/IP ethernet interface, protocol
- Diagnostics ethernet interface, function
- Switch ethernet interface, function
- RJ45 ethernet interface, connection system
- 995789 ethernet interface, connection pattern
- 8 ethernet interface, number of pins/wires
- 10 Mbit/s ethernet interface, transmission rate
- 100 Mbit/s ethernet interface, transmission rate
- 64AD max. address volume, inputs
- 512AD fieldbus interface, max. address volume for inputs
- 64AD max. address volume, outputs
- 512AD fieldbus interface, max. address volume for outputs
- Diagnostic memory system parameters
- Fail-safe response system parameters
- System start system parameters
- Channel alarms bundling module parameters
- Undervoltage diagnostics module parameters
- Channel alarms for undervoltage module parameters
- Process value representation of analogue modules module parameters
- Control unit CDSB configuration support
- CODESYS V3 configuration support
- GSDML file configuration support
- CoDeSys V3 with SoftMotion additional functions
- 512 MB RAM cPU data
- Dual Core 766 MHz cPU data
- Micro SD <= 32 GB storage medium
- USB memory stick <= 32 GB storage medium
- Electronics and sensors power supply, function
- Terminal strip power supply, connection type
- > 4 A and UL 2x terminal strip for power supply power supply, note on connection type
- Spring-loaded terminal power supply, connection system
- 995847 power supply, connection pattern
- 4 power supply, number of pins/wires
- 24V nominal dC operating voltage, electronics/sensors
- ± 25% permissible voltage fluctuations for electronics/sensors
- 0.2I2 power supply, conductor diameter
- 1.5I2 power supply, conductor diameter
- 0.2 - 2.5 mm² for flexible conductors without wire end sleeves power supply, note on conductor diameter
- 8A max. power supply
- Typically 150 mA intrinsic current consumption at nominal operating voltage for electronics/sensors
- 20MS power failure bridging
- 24 V sensor supply against 0 V sensor supply reverse polarity protection
- USB 2.0 uSB-interface
- CODESYS provided by Festo programming software
- 100 MB user program program memory
- Approx. 200 µs/1 k instruction processing time
- And others function modules
- Read CPX-E module diagnostics function modules
- CPX-E diagnostic status function modules
- Copy CPX-E diagnostic trace function modules
- 3WCH buffering time real-time clock
- 120 kB retentive data flag
- CODESYS variable concept flag
- -20GC to 70GC storage temperature
Documents
Accessories
General Accessories
Electrical Accessories
Need Help? Call an engineer at 1-802-880-3123
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET