$453.97
  • CTEU-CC
  • 1544198

Overview

Features

  • CC-Link protocol
  • 40 x 91 x 50 mm dimensions (W x l x h)
  • 40MM grid dimension
  • On electrical interface type of mounting
  • On electrical sub-base type of mounting
  • 90G product weight
  • IP65 degree of protection
  • IP67 degree of protection
  • In assembled state note on degree of protection
  • Unused connections sealed note on degree of protection
  • 2 - Moderate corrosion stress corrosion resistance class cRC
  • VDMA24364 zone III lABS (PWIS) conformity
  • To EU EMC Directive cE mark (see declaration of conformity)
  • In accordance with EU RoHS Directive cE mark (see declaration of conformity)
  • To UK instructions for EMC cE marking (see declaration of conformity)
  • To UK RoHS instructions cE marking (see declaration of conformity)
  • KC-EMV kC mark
  • RCM trademark approval
  • C UL us listed (OL) approval
  • RoHS-compliant note on materials
  • PA material housing
  • PS: Operating voltage for electronics and load supply lED display, product-specific
  • X1: System status of module at I-Port 1 lED display, product-specific
  • X2: System status of module at I-Port 2 lED display, product-specific
  • Err: Data transmission error lED display, bus-specific
  • Run: Bus active lED display, bus-specific
  • Communication fault diagnosis
  • System diagnostics diagnosis
  • Undervoltage diagnosis
  • DIL switch operator controls
  • Open style (screw terminal, 5-pin, IP20 protection) note on fieldbus interface
  • Optional connection technology with accessories: note on fieldbus interface
  • Serial interface module fieldbus interface
  • CC-LINK® field bus, protocol
  • Bus connection incoming/outgoing fieldbus interface, function
  • Socket field bus, connection type
  • Sub-D field bus, connection system
  • 995638 fieldbus interface, connection pattern
  • 9 field bus, connection pattern
  • Yes field bus interface, electrical isolation
  • 156 - 10000 kbit/s field bus interface, transmission rate
  • 16AD max. address volume, inputs
  • 16AD max. address volume, outputs
  • Activate diagnostics parameterisation
  • Fail-safe and idle response parameterisation
  • 1 ms per 1 byte of user data internal cycle time
  • System status can be mapped using process data additional functions
  • Electronics and load power supply, function
  • Plugs power supply, connection type
  • M12x1, A-coded according to EN 61076-2-101 power supply, connection system
  • 995383 power supply, connection pattern
  • 5 power supply, number of pins/wires
  • 18V operational voltage range dC
  • 30V operational voltage range dC
  • 24V nominal operating voltage dC
  • 4A max. power supply
  • Typ. 70 mA intern power consumption nominal operating voltage
  • -5GC ambient temperature to 50GC ambient temperature
  • -20GC to 70GC storage temperature