Festo CTEU-VN Bus Node
Fieldbus modules for use with pneumatic valve manifolds VTUG, MPA-L, and VTOC with a fieldbus protocol of VARAN. View other configurations.

- CTEU-VN
- 8087559
- CTEU-VN
- By Festo
- FREE Shipping on orders of $1,000 or more
Overview
Features
- 40 x 91 x 50 mm dimensions (W x l x h)
- 40MM grid dimension
- On electrical interface type of mounting
- On electrical sub-base type of mounting
- 98G product weight
- IP65 degree of protection
- IP67 degree of protection
- In assembled state note on degree of protection
- Unused connections sealed note on degree of protection
- 2 - Moderate corrosion stress corrosion resistance class cRC
- VDMA24364 zone III lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- RoHS-compliant note on materials
- PA material housing
- PS: Operating voltage for electronics and load supply lED display, product-specific
- X1: System status of module at I-Port 1 lED display, product-specific
- X2: System status of module at I-Port 2 lED display, product-specific
- XF1 AC: network data exchange, port 1 lED display, bus-specific
- XF1 LI: network active, port 1 lED display, bus-specific
- Communication fault diagnosis
- System diagnostics diagnosis
- Undervoltage diagnosis
- Ethernet fieldbus interface
- VARAN field bus, protocol
- Bus connection incoming/outgoing fieldbus interface, function
- 2x socket field bus, connection type
- M12x1, D-coded to EN 61076-2-101 field bus, connection system
- 995716 fieldbus interface, connection pattern
- 4 field bus, connection pattern
- Yes field bus interface, electrical isolation
- 100 Mbit/s field bus interface, transmission rate
- 32AD max. address volume, inputs
- 32AD max. address volume, outputs
- Fail-safe response parameterisation
- IO-Link mode parameterisation
- 1 ms per 1 byte of user data internal cycle time
- LASAL module configuration support
- FFT additional functions
- VARAN splitter additional functions
- Electronics and load power supply, function
- Plugs power supply, connection type
- M12x1, A-coded according to EN 61076-2-101 power supply, connection system
- 995383 power supply, connection pattern
- 5 power supply, number of pins/wires
- 18V operational voltage range dC
- 30V operational voltage range dC
- 24V nominal operating voltage dC
- 4A max. power supply
- Typ. 65 mA intern power consumption nominal operating voltage
- -5GC ambient temperature to 50GC ambient temperature
- -20GC to 70GC storage temperature
Documents
Need Help? Call an engineer at 1-802-880-3123
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET