Features

  • 5/2 double solenoid valve function
  • Electric type of actuation
  • 26MM construction width
  • 600L2 standard nominal flow rate
  • 0MPA operating pressure
  • 1MPA operating pressure
  • 0BAR operating pressure
  • 10BAR operating pressure
  • Poppet seat design
  • To EU Explosion Protection Directive (ATEX) cE mark (see declaration of conformity)
  • EPL Db (GB) explosion protection certification outside the eU
  • EPL Gb (GB) explosion protection certification outside the eU
  • To UK EX instructions cE marking (see declaration of conformity)
  • II 2G aTEX category gas
  • II 2D aTEX category dust
  • Ex h IIC T4 Gb explosion ignition protection type for gas
  • Ex h IIIC T130°C Db explosion ignition protection type for dust
  • -5°C <= Ta <= +40°C explosion ambient temperature
  • IP65 degree of protection
  • 5MM nominal size
  • 27MM grid dimension
  • With flow control option exhaust-air function
  • Soft sealing principle
  • Optional mounting position
  • Detenting manual override
  • Pilot actuated type of piloting
  • External pilot air supply
  • Non-reversible flow direction
  • 995755 symbol
  • Underlap lap
  • 0.12MPA pilot pressure
  • 0.8MPA pilot pressure
  • 1.2BAR pilot pressure
  • 8BAR pilot pressure
  • 25HZ max. switching frequency
  • 10MS switching time reversal
  • 2200MIS max. positive test pulse with 0 signal
  • 3700MIS max. negative test pulse with 1 signal
  • See solenoid coil, to be ordered separately characteristic coil data
  • Compressed air to ISO 8573-1:2010 [7:4:4] operating medium
  • Lubricated operation possible (in which case lubricated operation will always be required) note on operating and pilot medium
  • 1 - Low corrosion stress corrosion resistance class cRC
  • VDMA24364-B1/B2-L lABS (PWIS) conformity
  • -5GC media temperature
  • 40GC media temperature
  • Compressed air to ISO 8573-1:2010 [7:4:4] pilot medium
  • -5GC ambient temperature
  • 40GC ambient temperature
  • 260G product weight
  • Via F coil, to be ordered separately electrical connection
  • Either: type of mounting
  • On PR rail type of mounting
  • With through-hole type of mounting
  • M5 breather connection
  • M5 pilot exhaust port 82
  • M5 pilot exhaust port 84
  • M5 pilot air port 12
  • M5 pilot air port 14
  • RoHS-compliant note on materials
  • NBR material seals
  • TPE-U(PU) material seals
  • Die-cast aluminium material housing
  • -20GC to 60GC storage temperature
  • Pneumatic connection g1/8 , port 1
  • Pneumatic connection g1/8 , port 2
  • Pneumatic connection g1/8 , port 3
  • Pneumatic connection g1/8 , port 4
  • Pneumatic connection g1/8 , port 5