$16.91
  • NEBA-M12W5-U-2.5-N-LE3
  • 8078245

Overview

Features

  • EN 61076-2-101 conforms to standard
  • EN 61984 conforms to standard
  • C UL us listed (OL) approval
  • The connecting cable connects field devices (sensors, actuators) with controllers. intended use
  • UL E253748 certificate issuing authority
  • Without inscription label holder cable designation
  • 100 frequency of connection
  • 56G product weight
  • Meets the requirements of IEC 61010-1 and 61010-2-202, in particular for electrically operated valves from Festo. instructions on use
  • Only energy-limited circuits with a maximum current of 4 A at a max. open circuit voltage of 30 V DC are permissible for supplying electrically actuated valves from Festo. instructions on use
  • Field device side electrical connection 1, function
  • Round electrical connection 1, design
  • Socket electrical connection 1, connection type
  • Angled electrical connection 1, cable outlet
  • M12x1, A-coded to EN 61076-2-101 electrical connection 1, connector system
  • 5 electrical connection 1, number of connections/cores
  • 3 electrical connection 1, used connections/cores
  • Screw-type lock with 13 mm hexagon and longitudinal knurl electrical connection 1, type of mounting
  • 991867 electrical connection 1, connection pattern
  • Pin 1 = BN electrical connection 1, terminal allocation
  • Pin 3 = BU electrical connection 1, terminal allocation
  • Pin 4 = BK electrical connection 1, terminal allocation
  • None electrical connection 1, display
  • Controller side electrical connection 2, function
  • Cable electrical connection 2, connection type
  • Open end electrical connection 2, connector system
  • 3 electrical connection 2, number of connections/cores
  • 3 electrical connection 2, used connections/cores
  • Pin 1 = BN electrical connection 2, terminal allocation
  • Pin 3 = BU electrical connection 2, terminal allocation
  • Pin 4 = BK electrical connection 2, terminal allocation
  • None electrical connection 2, display
  • 0V operational voltage range dC
  • 250V operational voltage range dC
  • 0 - 30 V for UL applications note on operational voltage range dC
  • 0V operational voltage range aC
  • 250V operational voltage range aC
  • 0 - 30 V for UL applications note on operational voltage range aC
  • 4A current rating at 40° c
  • 2.5KV immunity to surge
  • 2.5M cable length
  • Suitable for energy chains/robot applications cable characteristic
  • Abrasion-resistant cable characteristic
  • Low adhesion cable characteristic
  • Flame-retardant and self-extinguishing cable characteristic
  • Test conditions on request test conditions cable
  • Torsional resistance: > 300,000 cycles, ± 270°/0.1 m test conditions cable
  • Bending fatigue strength: > 50000 cycles, bending radius 5 mm test conditions cable
  • Energy chain: > 5 million cycles, bending radius 28 mm test conditions cable
  • Tested at 23 °C notes on test conditions cable
  • 12MM bending radius, fixed cable
  • 39MM bending radius, moving cable
  • 3.8MM cable diameter
  • 3 x 0.25 mm² cable structure
  • 0.25I2 nominal cross section conductor
  • Sheath removed wire ends
  • Cut off bluntly wire ends
  • IP65 degree of protection
  • IP68 degree of protection
  • IP69K degree of protection
  • In assembled state note on degree of protection
  • UV resistant special characteristics
  • Hydrolysis-resistant special characteristics
  • Resistant to cooling lubricants special characteristics
  • Resistant to microbes special characteristics
  • Oil resistant special characteristics
  • Ozone-resistant special characteristics
  • Application areas with direct exposure to outdoor climatic influences Class D1 based on IEC 60654-1 outdoor applications
  • -40GC ambient temperature
  • 85GC ambient temperature
  • -40 - 50 °C for UL applications note on ambient temperature
  • Note derating note on ambient temperature
  • -20GC ambient temperature with moving cable
  • 85GC ambient temperature with moving cable
  • -20 - 50 °C for UL applications note on the ambient temperature with flexible cable installation
  • -25GC storage temperature
  • 55GC storage temperature
  • Temporarily during transport in packaging -40 ... 85 °C note on storage temperature
  • Max. 93% at 40 °C relative air humidity
  • <= 2000 m NHN nominal altitude of use
  • II overvoltage category
  • To EU Low Voltage Directive cE mark (see declaration of conformity)
  • In accordance with EU RoHS Directive cE mark (see declaration of conformity)
  • To UK RoHS instructions cE marking (see declaration of conformity)
  • To UK regulations for electrical equipment cE marking (see declaration of conformity)
  • VDMA24364-B2-L lABS (PWIS) conformity
  • Metals with more than 1% copper, zinc or nickel by mass are excluded from use. Exceptions are nickel in steel, chemically nickel-plated surfaces, printed circuit boards, cables, electrical plug connectors and coils suitability for the production of li-ion batteries
  • Class 4 according to ISO 14644-1 cleanroom class
  • CFC-free note on materials
  • RoHS-compliant note on materials
  • Cadmium-free note on materials
  • Free of halogen note on materials
  • Free of phosphoric acid ester note on materials
  • 3 pollution degree
  • 1 - Low corrosion stress corrosion resistance class cRC
  • TPE-U(PUR) material cable sheath
  • Grey cable sheath colour
  • TPE-U(PUR) material housing
  • Black housing colour
  • Die-cast zinc, nickel-plated material screw-type lock
  • FPM material seals
  • Gold-plated copper alloy material electrical contact
  • PP material insulating sheath