Festo SFAW-100T-X-E-PNLK-PNVBA-M12 Flow Sensor
Air flow sensor for Max. 100l/min flow with Standard input and Standard output. View other configurations.
- SFAW-100T-X-E-PNLK-PNVBA-M12
- 8036890
- SFAW-100T-X-E-PNLK-PNVBA-M12
- By Festo
- FREE Shipping on orders of $1,000 or more
- FREE Lifetime Tech Support
Overview
Features
- 995566 symbol
- RCM trademark approval
- C UL us listed (OL) approval
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- RoHS-compliant note on materials
- Flow rate measured variable
- Temperature measured variable
- Unidirectional flow direction
- P1 -> P2 flow direction
- Flow: Vortex measurement method
- Temperature: PT1000 measurement method
- 5L2 start value for flow rate measuring range
- 100L2 end value for flow rate measuring range
- 0GC temperature measurement start value
- 90GC temperature measurement end value
- 0MPA operating pressure
- 1.2MPA operating pressure
- 0BAR operating pressure
- 12BAR operating pressure
- Max. 1.2 MPa (12 bar / 174 psi) at 40 °C note on operating pressure
- Max. 0.6 MPa (6 bar / 87 psi) at 90 °C note on operating pressure
- 4MPA overload pressure
- 40BAR overload pressure
- 580PSI overload pressure
- Liquid media operating medium
- Water operating medium
- Neutral fluids operating medium
- Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured. note on operating and pilot medium
- 0GC media temperature
- 90GC media temperature
- 23GC nominal temperature
- ± 2% FS for flow rate <= 50% FS accuracy of flow rate
- ± 3% of measured value for flow rate >= 50% FS accuracy of flow rate
- 2GC accuracy temperature in ± °C
- < ± 0.5% FS for flow rate <= 50% FS repetition accuracy of flow rate
- < ± 1% o.m.v. for flow rate >= 50% FS repetition accuracy of flow rate
- Typ. ± 0.05%FS/K temperature coefficient span in ± %FS/K
- 2 x PNP or 2 x NPN, switchable switching output
- Window comparator switching function
- Threshold value comparator switching function
- Freely programmable switching function
- N/C or N/O contact, switchable switching element function
- 100MA max. output current
- 0 - 10 V analogue output
- 4 - 20 mA analogue output
- 1 - 5 V analogue output
- 0L2 flow characteristic curve start value
- 100L2 flow characteristic curve end value
- 0GC temperature characteristic curve start value
- 100GC temperature characteristic curve end value
- 500OHM max. load resistance current output
- 15KOH min. load resistance voltage output
- Yes short circuit current rating
- Available overload protection
- IO-Link® protocol
- Device V 1.1 iO-Link, protocol version
- Smart sensor profile iO-Link, profile
- Binary data channel (BDC) iO-Link, function classes
- Process data variable (PDV) iO-Link, function classes
- Identification iO-Link, function classes
- Diagnostics iO-Link, function classes
- Teach channel iO-Link, function classes
- COM2 (38.4 kBaud) iO-Link, communication mode
- Yes iO-Link, sIO-Mode support
- A iO-Link, port class
- 0 bytes iO-Link, process data length oUT
- 5 bytes iO-Link, process data length iN
- 1 bit BDC (temperature monitoring) iO-Link, process data content iN
- 1 bit BDC (volume monitoring) iO-Link, process data content iN
- 14 bit PDV (measured flow value) iO-Link, process data content iN
- 14 bit PDV (measured temperature value) iO-Link, process data content iN
- 2 bit BDC (flow monitoring) iO-Link, process data content iN
- 32-bit volume measurement iO-Link, service data iN
- 5 ms iO-Link, min. cycle time
- 500KB iO-Link, data storage required
- 18V operational voltage range dC
- 30V operational voltage range dC
- For all electrical connections reverse polarity protection
- Plugs electrical connection 1, connection type
- M12x1, A-coded to EN 61076-2-101 electrical connection 1, connector system
- 5 electrical connection 1, number of connections/cores
- Screw-type lock electrical connection 1, type of mounting
- 995383 electrical connection 1, connection pattern
- 20 m with IO-Link® operation max. cable length
- 30 m max. cable length
- Optional mounting position
- Connection by the user fluid connection
- 140G product weight
- PA-reinforced material housing
- EPDM (peroxide) material in contact with the medium
- ETFE material in contact with the medium
- Stainless steel material in contact with the medium
- PA6T/6I reinforced material in contact with the medium
- US gal displayable units
- US gal/min displayable units
- Cft displayable units
- Cft/min displayable units
- L displayable units
- L/h displayable units
- L/min displayable units
- M3 displayable units
- °C displayable units
- °F displayable units
- IP65 degree of protection
- 3 - high corrosion stress corrosion resistance class cRC
- VDMA24364-B2-L lABS (PWIS) conformity
- 0GC ambient temperature to 50GC ambient temperature
Documents
Accessories
Mounting Accessories
Electrical Accessories
Need Help? Call an engineer at 1-802-880-3123
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET