Festo SPAU-P10R-H-Q4D-LK-V-M12D Pressure Sensor
Relative pressure sensor for 0 to 10bar pressure range with Push-in connector 4mm connection. View other configurations.
- SPAU-P10R-H-Q4D-LK-V-M12D
- 8003349
- SPAU-P10R-H-Q4D-LK-V-M12D
- By Festo
- FREE Shipping on orders of $1,000 or more
- FREE Lifetime Tech Support
Overview
Features
- 995411 symbol
- RCM trademark approval
- C UL us listed (OL) approval
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- KC-EMV kC mark
- RoHS-compliant note on materials
- Relative pressure measured variable
- Piezoresistive pressure sensor measurement method
- 0MPA start value for pressure measuring range
- 0BAR start value for pressure measuring range
- 0PSI start value for pressure measuring range
- 1MPA end value for pressure measuring range
- 10BAR end value for pressure measuring range
- 145PSI end value for pressure measuring range
- 15BAR max. overload pressure
- 1.5MPA overload pressure
- 15BAR overload pressure
- 217.5PSI overload pressure
- Compressed air to ISO 8573-1:2010 [7:4:4] operating medium
- Inert gases operating medium
- Lubricated operation possible note on operating and pilot medium
- 0GC media temperature
- 50GC media temperature
- 12BIT resolution aDC
- 1.5YUQ accuracy in ± % fS
- 0.3YUQ repetition accuracy in ± %FS
- 0.05YUP temperature coefficient in ± %FS/K
- 2xPNP switching output
- Freely programmable switching function
- N/C or N/O contact, switchable switching element function
- 100MA max. output current
- 0 - 10 V analogue output
- 3MS rise time
- 500OHM max. load resistance current output
- 10KOH min. load resistance voltage output
- Yes short circuit current rating
- IO-Link® protocol
- Device V 1.1 iO-Link, protocol version
- Smart sensor profile iO-Link, profile
- Binary data channel (BDC) iO-Link, function classes
- Process data variable (PDV) iO-Link, function classes
- Identification iO-Link, function classes
- Diagnostics iO-Link, function classes
- Teach channel iO-Link, function classes
- COM2 (38.4 kBaud) iO-Link, communication mode
- Yes iO-Link, sIO-Mode support
- A iO-Link, port class
- 0 bytes iO-Link, process data length oUT
- 2 bytes iO-Link, process data length iN
- 14 bit PDV (pressure measurement value) iO-Link, process data content iN
- 2 bit BDC (pressure monitoring) iO-Link, process data content iN
- 3 ms iO-Link, min. cycle time
- 500KB iO-Link, data storage required
- 20V operational voltage range dC
- 30V operational voltage range dC
- For all electrical connections reverse polarity protection
- Plugs electrical connection 1, connection type
- M12x1, A-coded to EN 61076-2-101 electrical connection 1, connector system
- 4 electrical connection 1, number of connections/cores
- 995386 electrical connection 1, connection pattern
- With H-rail type of mounting
- Optional mounting position
- 65G product weight
- LED display type
- MPa displayable units
- Bar displayable units
- InH2O displayable units
- InHg displayable units
- KPa displayable units
- Kgf/cm² displayable units
- MmHg displayable units
- Psi displayable units
- IO-Link® setting options
- IO-Link protection against tampering
- 0% setting range threshold value
- 100% setting range threshold value
- 0% setting range hysteresis
- 90% setting range hysteresis
- IP65 degree of protection
- IP67 degree of protection
- 2 - Moderate corrosion stress corrosion resistance class cRC
- VDMA24364-B1/B2-L lABS (PWIS) conformity
- 0GC ambient temperature to 50GC ambient temperature
- Pneumatic connection qS-4
Documents
Accessories
Tubes
Mounting Accessories
Electrical Accessories