- CPX-AP-I-PB-M12
- 8086608
- CPX-AP-I-PB-M12
- By Festo
- FREE Shipping on orders of $1,000 or more
- FREE Lifetime Tech Support
Overview
Features
- 45 x 170 x 35 mm dimensions (W x l x h)
- On H-rail via accessories type of mounting
- With through-hole type of mounting
- 56 max. number of modules
- 186G product weight
- 5 - 95% relative air humidity
- Non-condensing relative air humidity
- IP65 degree of protection
- IP67 degree of protection
- Unused connections sealed note on degree of protection
- 1 - Low corrosion stress corrosion resistance class cRC
- 50 m system communication max. cable length
- VDMA24364-B2-L lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- C UL us listed (OL) approval
- UL E239998 certificate issuing authority
- RoHS-compliant note on materials
- PA material housing
- PC material housing
- Die-cast zinc, nickel-plated material housing
- FPM material o-ring
- Buffer error LED (BF) diagnostics via lED
- Diagnostics per module diagnostics via lED
- Power supply, electronics/sensors diagnostics via lED
- Load power supply diagnostics via lED
- System diagnostics diagnostics via lED
- Service required diagnostics via lED
- APDD invalid diagnostics via bus
- Load switch-off diagnostics via bus
- Communication with AP module interrupted diagnostics via bus
- Electronics/sensors overvoltage diagnostics via bus
- Load overvoltage diagnostics via bus
- Electronics/sensors undervoltage diagnostics via bus
- Load undervoltage diagnostics via bus
- Terminating resistor at socket possible note on fieldbus interface
- PROFIBUS fieldbus interface
- PROFIBUS DP-V1 field bus, protocol
- Incoming bus connection fieldbus interface, function
- Plugs field bus, connection type
- M12x1, B-encoded to EN 61076-2-101 field bus, connection system
- 5 field bus, connection pattern
- Yes field bus interface, electrical isolation
- 1.5 Mbps field bus interface, transmission rate
- 12 Mbit/s field bus interface, transmission rate
- 187.5 kbit/s field bus interface, transmission rate
- 19.2 kbit/s field bus interface, transmission rate
- 3 Mbit/s field bus interface, transmission rate
- 500 kbit/s field bus interface, transmission rate
- 6 Mbit/s field bus interface, transmission rate
- 9.6 kbit/s field bus interface, transmission rate
- 93.75 kbit/s field bus interface, transmission rate
- PROFIBUS fieldbus interface 2, type
- PROFIBUS DP-V1 fieldbus interface 2, protocol
- Outgoing bus connection fieldbus interface 2, function
- Socket fieldbus interface 2, connection type
- M12x1, B-encoded to EN 61076-2-101 fieldbus interface 2, connection technology
- 5 fieldbus interface 2, number of pins/wires
- Yes fieldbus interface 2, galvanic isolation
- 1.5 Mbps fieldbus interface 2, transmission rate
- 12 Mbps fieldbus interface 2, transmission rate
- 187.5 kbps fieldbus interface 2, transmission rate
- 19.2 kbps fieldbus interface 2, transmission rate
- 3 Mbps fieldbus interface 2, transmission rate
- 500 kbps fieldbus interface 2, transmission rate
- 6 Mbps fieldbus interface 2, transmission rate
- 9.6 kbps fieldbus interface 2, transmission rate
- 93.75 kbps fieldbus interface 2, transmission rate
- 244AD max. address volume, inputs
- 244AD max. address volume, outputs
- GSD file configuration support
- System communication XF20 OUT / XF21 OUT communication interface, function
- 2x socket communication interface, connection type
- M8x1, D-coded according to EN 61076-2-114 communication interface, connection technology
- 4 communication interface, number of pins/wires
- AP communication interface, protocol
- Yes communication interface, shielding
- Incoming electronics/sensors and load power supply, function
- Plugs power supply, connection type
- M8x1, A-coded to EN 61076-2-104 power supply, connection system
- 4 power supply, number of pins/wires
- Outgoing electronics/sensors and load power transmission, function
- Socket power transmission, connection type
- M8x1, A-coded to EN 61076-2-104 power transmission, connection technology
- 4 power transmission, number of pins/wires
- SELV/PELV fixed power supplies required note regarding operating voltage
- Note voltage drop note regarding operating voltage
- 24V nominal operating voltage dC of load
- ± 25 % permissible voltage fluctuation of load
- 24V nominal dC operating voltage, electronics/sensors
- ± 25% permissible voltage fluctuations for electronics/sensors
- 2 x 4 A (external fuse required) max. power supply
- Typically 80 mA intrinsic current consumption at nominal operating voltage for electronics/sensors
- Typically 5 mA intrinsic current consumption at nominal operating voltage load
- 10MS power failure bridging
- Yes reverse polarity protection
- -20GC ambient temperature to 50GC ambient temperature
- -40GC to 70GC storage temperature