Festo CTEU-DN Bus Node
Fieldbus modules for use with pneumatic valve manifolds VTUG, MPA-L, and VTOC with a fieldbus protocol of DeviceNet. View other configurations.
- CTEU-DN
- 570039
Overview
Features
- DeviceNet protocol
- 40 x 91 x 50 mm dimensions (W x l x h)
- 40MM grid dimension
- On electrical interface type of mounting
- On electrical sub-base type of mounting
- 90G product weight
- IP65 degree of protection
- IP67 degree of protection
- In assembled state note on degree of protection
- Unused connections sealed note on degree of protection
- 2 - Moderate corrosion stress corrosion resistance class cRC
- VDMA24364 zone III lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- C UL us listed (OL) approval
- RoHS-compliant note on materials
- PA material housing
- PC material housing
- PS: Operating voltage for electronics and load supply lED display, product-specific
- X1: System status of module at I-Port 1 lED display, product-specific
- X2: System status of module at I-Port 2 lED display, product-specific
- IO: I/O status lED display, bus-specific
- MNS: Network status lED display, bus-specific
- Communication fault diagnosis
- System diagnostics diagnosis
- Undervoltage diagnosis
- DIL switch operator controls
- Optional connection technology with accessories: micro style (plug/socket M12x1 A-coded, 5-pin, IP65 protection), open style (terminal strip, 5-pin, IP20 protection) note on fieldbus interface
- Open style (screw terminal, 5-pin, IP20 protection) note on fieldbus interface
- Optional connection technology with accessories: note on fieldbus interface
- CAN bus fieldbus interface
- DeviceNet field bus, protocol
- Bus connection incoming/outgoing fieldbus interface, function
- Plugs field bus, connection type
- Sub-D field bus, connection system
- 995639 fieldbus interface, connection pattern
- 9 field bus, connection pattern
- Yes field bus interface, electrical isolation
- 125 kbit/s field bus interface, transmission rate
- 250 kbit/s field bus interface, transmission rate
- 500 kbit/s field bus interface, transmission rate
- 8AD max. address volume, inputs
- 8AD max. address volume, outputs
- Diagnostic behaviour parameterisation
- Fail-safe and idle response parameterisation
- 1 ms per 1 byte of user data internal cycle time
- EDS file configuration support
- Acyclic data access via "Explicit Message" additional functions
- QuickConnect additional functions
- System status can be mapped using process data additional functions
- Electronics and load power supply, function
- Plugs power supply, connection type
- M12x1, B-encoded to EN 61076-2-101 power supply, connection system
- 995719 power supply, connection pattern
- 5 power supply, number of pins/wires
- 18V operational voltage range dC
- 30V operational voltage range dC
- 24V nominal operating voltage dC
- 4A max. power supply
- Typ. 65 mA intern power consumption nominal operating voltage
- -5GC ambient temperature to 50GC ambient temperature
- -20GC to 70GC storage temperature
This product is an accessory for the following products:
Documents
Accessories
Need Help? Call an engineer at 1-802-880-3123
We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET