Festo CTEU-AS Bus Node
Fieldbus modules for use with pneumatic valve manifolds VTUG, MPA-L, and VTOC with a fieldbus protocol of AS-interface. View other configurations.
- CTEU-AS
- 572555
Overview
Features
- AS-Interface protocol
- 40 x 91 x 50 mm dimensions (W x l x h)
- 40MM grid dimension
- On electrical interface type of mounting
- On electrical sub-base type of mounting
- 90G product weight
- IP65 degree of protection
- IP67 degree of protection
- In assembled state note on degree of protection
- Unused connections sealed note on degree of protection
- 2 - Moderate corrosion stress corrosion resistance class cRC
- VDMA24364 zone III lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- C UL us listed (OL) approval
- RoHS-compliant note on materials
- PA material housing
- PS: Operating voltage for electronics and load supply lED display, product-specific
- X1: System status of module at I-Port 1 lED display, product-specific
- AS-i: AS-Interface mode lED display, bus-specific
- Communication fault diagnosis
- System diagnostics diagnosis
- Undervoltage diagnosis
- DIL switch operator controls
- AS-Interface fieldbus interface
- AS-Interface field bus, protocol
- Incoming bus connection fieldbus interface, function
- Power supply fieldbus interface, function
- Plugs field bus, connection type
- M12x1, A-coded according to EN 61076-2-101 field bus, connection system
- 995386 fieldbus interface, connection pattern
- 4 field bus, connection pattern
- Outgoing bus connection fieldbus interface 2, function
- Power supply fieldbus interface 2, function
- Socket fieldbus interface 2, connection type
- M12x1, A-coded to EN 61076-2-101 fieldbus interface 2, connection technology
- 995385 fieldbus interface 2, connection pattern
- 4 fieldbus interface 2, number of pins/wires
- 2AD max. address volume, inputs
- 2AD max. address volume, outputs
- Watchdog disable parameterisation
- Watchdog enable parameterisation
- 10 ms internal cycle time
- None configuration support
- 20V operational voltage range dC
- 31.6V operational voltage range dC
- 30V nominal operating voltage dC
- 4A max. power supply
- Typ. 50 mA intern power consumption nominal operating voltage
- -5GC ambient temperature to 50GC ambient temperature
- -20GC to 70GC storage temperature