Festo CTEU-EP Bus Node
Fieldbus modules for use with pneumatic valve manifolds VTUG, MPA-L, and VTOC with a fieldbus protocol of EtherNet/IP. View other configurations.
- CTEU-EP
- 2798071
Overview
Features
- EtherNet/IP protocol
- Modbus® TCP protocol
- 40 x 91 x 50 mm dimensions (W x l x h)
- 98G product weight
- IP65 degree of protection
- IP67 degree of protection
- 2 - Moderate corrosion stress corrosion resistance class cRC
- VDMA24364 zone III lABS (PWIS) conformity
- To EU EMC Directive cE mark (see declaration of conformity)
- In accordance with EU RoHS Directive cE mark (see declaration of conformity)
- To UK instructions for EMC cE marking (see declaration of conformity)
- To UK RoHS instructions cE marking (see declaration of conformity)
- KC-EMV kC mark
- RCM trademark approval
- C UL us listed (OL) approval
- RoHS-compliant note on materials
- PA material housing
- PS: Operating voltage for electronics and load supply lED display, product-specific
- X1: System status of module at I-Port 1 lED display, product-specific
- X2: System status of module at I-Port 2 lED display, product-specific
- NS: Network status lED display, bus-specific
- TP1: Network active port 1 lED display, bus-specific
- TP2: Network active port 2 lED display, bus-specific
- Communication fault diagnosis
- System diagnostics diagnosis
- Undervoltage diagnosis
- DIL switch operator controls
- 2x socket, M12x1, 4-pin, D-coded field bus interface
- 64AD max. address volume, inputs
- 64AD max. address volume, outputs
- Diagnostic behaviour parameterisation
- Fail-safe and idle response parameterisation
- 10/100 Mbit/s baud rate
- 1 ms per 1 byte of user data internal cycle time
- EDS file configuration support
- AddressConflictDetection (ACD) additional functions
- Acyclic data access via "Explicit Message" additional functions
- EtherNet/IP Quickconnect additional functions
- IP addressing via DHCP, DIL switch, fieldbus or FFT additional functions
- Integrated switch additional functions
- Ring topology (DLR) additional functions
- SNMP additional functions
- Start-up parameterisation in plain text via fieldbus additional functions
- System status can be mapped using process data additional functions
- Web servers additional functions
- 18V operational voltage range dC
- 30V operational voltage range dC
- 24V nominal operating voltage dC
- 4A max. power supply
- Typ. 65 mA intern power consumption nominal operating voltage
- -5GC ambient temperature to 50GC ambient temperature
- -20GC to 70GC storage temperature